VCP-DCV (2V0-21.23) - Fact Sheet

Quick Reference

Exam Code: 2V0-21.23 Duration: 135 minutes Questions: 70 (multiple choice, single and multiple answer) Passing Score: 300 / 500 Cost: $250 USD

Official 2V0-21.23 Exam Prep Guide VMware Configuration Maximums Tool - authoritative source for all maximums VMware Compatibility Guide - HCL


vSphere 8 Configuration Maximums (high-yield)

Source: configmax.broadcom.com (vSphere 8.0 U3).

Per virtual machine

Resource Max
vCPUs per VM 768
RAM per VM 24 TB
Virtual NICs per VM 10
Virtual SCSI adapters 4
Virtual disks per VM 256 (PVSCSI), 60 (LSI), 32k (NVMe)
Virtual disk size 62 TB
Virtual NVMe controllers per VM 4
PCI passthrough devices per VM 32
vGPUs per VM 8
Serial ports per VM 32

Per ESXi host

Resource Max
Logical CPUs per host 1,920
RAM per host 24 TB
VMs per host 1,024
Powered-on VMs per host 1,024
Virtual NICs per host 4,096
Datastores per host (VMFS) 1,024
LUNs per host 1,024
Paths per host 4,096
Paths per LUN 32
Concurrent vMotions per host (10 GbE) 8
Concurrent vMotions per host (1 GbE) 4

Per cluster

Resource Max
Hosts per non-vSAN HA/DRS cluster 96
Hosts per vSAN cluster (standard) 96
Hosts per vSAN stretched cluster 30 (15 per site + 1 witness)
VMs per cluster 10,000
VMs per host (powered on) 1,024
FT-protected VMs per cluster 128
FT-protected VMs per host 4

Note. vSphere 7 capped clusters at 64 hosts. The 96-host cap is a vSphere 8 increase. Some study material still says 64; trust configmax.broadcom.com.

Per vCenter Server

Resource Max
Hosts per vCenter 2,500
Powered-on VMs per vCenter 40,000
Registered VMs per vCenter 45,000
Linked vCenters (Enhanced Linked Mode) 15
Hosts across linked vCenters 15,000
Powered-on VMs across linked vCenters 150,000

vSphere Distributed Switch (vDS)

Resource Max
vDS instances per vCenter 128
Hosts per vDS 2,000
Distributed port groups per vDS 10,000
Static ports per vDS 60,000
Distributed ports per vCenter 60,000

VCSA Sizing (Tiny / Small / Medium / Large / X-Large)

Size vCPU RAM Storage (default) Hosts VMs
Tiny 2 14 GB 463 GB 10 100
Small 4 21 GB 533 GB 100 1,000
Medium 8 30 GB 658 GB 400 4,000
Large 16 39 GB 989 GB 1,000 10,000
X-Large 24 58 GB 1,786 GB 2,500 45,000

Storage profiles add additional disk for /storage/seat (stats/events/alarms/tasks): Default, Large, X-Large.


License Editions and Subscription Bundles

Pre-Broadcom (legacy perpetual SKUs - still on questions you may see)

Edition Key Features
vSphere Standard ESXi, vCenter Standard, basic HA, vMotion
vSphere Enterprise Plus Adds DRS, Storage DRS, vDS, Host Profiles, FT (multi-vCPU), Storage I/O Control, Network I/O Control
vSphere with Operations Management Adds vRealize Operations
vSphere Essentials Plus Kit Up to 3 hosts, 2 sockets each, small business bundle

Post-Broadcom subscription bundles (Nov 2023 onward)

VMware retired most perpetual licenses and consolidated into two main subscription bundles:

Bundle Includes Target
VCF (VMware Cloud Foundation) vSphere Enterprise Plus, vSAN, NSX, Aria Suite, HCX, full SDDC stack Enterprise private cloud
VVF (VMware vSphere Foundation) vSphere Enterprise Plus, vSAN (limited 100 GiB/core), Aria Operations, Aria Log Insight Mid-market virtualization
vSphere Standard Standalone, kept for small deployments Small business / edge
vSphere Essentials Plus Small-business bundle, kept post-Broadcom <100 VMs, 3 hosts

VCF is licensed per-core (16-core minimum per CPU). VVF is also per-core. Standalone vSphere Standard is still per-CPU with 32-core minimum.


ESXi Boot Media Requirements (vSphere 8)

  • Boot device must be at least 32 GB.
  • USB / SD-card-only boot is deprecated: vSphere 8 still allows it but with persistent local disk for /scratch and tools, and shows warnings. New deployments should use a dedicated drive.
  • ESX-OSData partition holds /scratch, system swap, ESX-OSData; sized 32-128 GB depending on disk size.
  • M.2 SATA / NVMe SSD or local HDD/SSD recommended.

VM Hardware Versions (compatibility)

HW Version Introduced Max vCPU Max RAM Notes
11 vSphere 6.0 128 4 TB
13 vSphere 6.5 128 6 TB
14 vSphere 6.7 128 6 TB
15 vSphere 6.7 U2 256 6 TB
17 vSphere 7.0 256 6 TB vTPM, vWatchdog Timer
19 vSphere 7.0 U2 768 24 TB
20 vSphere 8.0 768 24 TB vNVMe 1.3, vGPU profiles
21 vSphere 8.0 U2 768 24 TB NVMe 1.3 controller, NVMe TRIM/UNMAP

vmx-XX is the on-disk identifier. Older VMs run fine on newer hosts, but newer features need a HW upgrade.


esxcli Cheat Sheet

esxcli is the modern host-level CLI. Run on the ESXi shell or via SSH.

Host info

esxcli system version get
esxcli system hostname get
esxcli system maintenanceMode get
esxcli system maintenanceMode set --enable=true
esxcli hardware platform get
esxcli hardware cpu list
esxcli hardware memory get

Networking

esxcli network nic list                              # physical NICs (vmnicX)
esxcli network nic get -n vmnic0
esxcli network ip interface list                     # vmkernel ports (vmkX)
esxcli network ip interface ipv4 get
esxcli network vswitch standard list
esxcli network vswitch standard portgroup list
esxcli network vswitch standard add -v vSwitch1
esxcli network vswitch standard uplink add -u vmnic1 -v vSwitch1
esxcli network firewall ruleset list
esxcli network firewall ruleset set -e true -r sshServer

Storage

esxcli storage core adapter list
esxcli storage core device list
esxcli storage core path list
esxcli storage filesystem list                       # mounted datastores
esxcli storage vmfs extent list
esxcli storage nfs list
esxcli storage nfs add -H 10.0.0.5 -s /export/nfs01 -v NFS01
esxcli storage core device set -d <NAA.id> --state=on

vSAN

esxcli vsan cluster get
esxcli vsan cluster list
esxcli vsan storage list
esxcli vsan health cluster list
esxcli vsan policy getdefault

VM operations

vim-cmd vmsvc/getallvms                              # list VMs (use vim-cmd, not esxcli)
vim-cmd vmsvc/power.on <vmid>
vim-cmd vmsvc/power.off <vmid>
vim-cmd vmsvc/snapshot.create <vmid>
esxcli vm process list                                # running VM worlds
esxcli vm process kill --type=soft --world-id=<wid>

Software / patching

esxcli software vib list
esxcli software vib install -d /vmfs/volumes/datastore1/patch.zip
esxcli software profile update -p <profile> -d <depot>
esxcli software vib remove -n <vibname>

Logs

esxcli system syslog config get
esxcli system syslog config set --loghost='udp://10.0.0.50:514'
esxcli system syslog reload

PowerCLI Cheat Sheet

PowerShell module for vCenter / ESXi automation. Install: Install-Module VMware.PowerCLI.

Connect / disconnect

Connect-VIServer -Server vcenter.lab.local -User administrator@vsphere.local
Disconnect-VIServer -Server vcenter.lab.local -Confirm:$false
Get-VIServer

Inventory

Get-Datacenter
Get-Cluster
Get-VMHost
Get-VMHost esx01.lab.local | Format-List Name, Version, Build, ConnectionState, PowerState
Get-Datastore
Get-VirtualSwitch -VMHost esx01
Get-VDSwitch
Get-VDPortgroup

VM operations

Get-VM
Get-VM web01 | Select Name, NumCpu, MemoryGB, PowerState, Folder, ResourcePool
New-VM -Name web02 -Template "Ubuntu-22-Template" -Datastore ds01 -ResourcePool ProdPool
Start-VM -VM web01
Stop-VM -VM web01 -Confirm:$false
Restart-VMGuest -VM web01
Move-VM -VM web01 -Destination esx02.lab.local                   # vMotion
Move-VM -VM web01 -Datastore ds02                                  # Storage vMotion
New-Snapshot -VM web01 -Name "before-patch" -Memory -Quiesce
Get-Snapshot -VM web01
Remove-Snapshot -Snapshot $snap -Confirm:$false

Bulk reporting

Get-VM | Select Name, NumCpu, MemoryGB,
    @{N='UsedSpaceGB';E={[math]::Round($_.UsedSpaceGB,1)}},
    @{N='Host';E={$_.VMHost.Name}} |
    Export-Csv vm-inventory.csv -NoTypeInformation

Cluster / DRS / HA

Get-Cluster Prod | Select Name, HAEnabled, DrsEnabled, DrsAutomationLevel
Set-Cluster -Cluster Prod -DrsAutomationLevel FullyAutomated -Confirm:$false
New-DrsRule -Cluster Prod -Name "AffinityWeb" -KeepTogether -VM web01,web02

Host config

Get-VMHost esx01 | Set-VMHost -State Maintenance
Get-VMHost esx01 | Set-VMHost -State Connected
Get-VMHost | Get-VMHostNetworkAdapter -VMKernel

Networking - vSwitch (VSS) vs vSphere Distributed Switch (vDS)

Feature VSS (Standard) vDS (Distributed)
Scope Per-host Cluster / datacenter, managed at vCenter
Configuration Manual per host Centralized
Edition required Any Enterprise Plus / VCF / VVF
LACP No Yes (LACPv2)
NetFlow No Yes
Port mirroring No Yes
Network I/O Control (NIOC) No Yes (v3 in vSphere 8)
Private VLANs No Yes
Health check (MTU, teaming, VLAN) No Yes

vSwitch policy stack

  • Security: Promiscuous mode, MAC address changes, Forged transmits (default Reject for the latter two on VSS, Accept on default vDS)
  • Traffic shaping: Average bandwidth, peak, burst (egress only on VSS, ingress+egress on vDS)
  • Teaming and failover: Load balancing (Route based on originating port ID, IP hash, source MAC, NIC load), active/standby/unused uplinks

NIC teaming load-balancing modes

Mode When to use Caveats
Route based on originating port ID Default; safe everywhere No real load distribution per VM
Route based on source MAC hash Rarely used Similar to port ID
Route based on IP hash EtherChannel / static LAG only Requires switch-side LAG
Route based on physical NIC load Best for vDS "Load Based Teaming" (LBT); rebalances every 30s
Use explicit failover order Failover only No load balancing

Storage

VMFS versions

Version vSphere Block size Max LUN Max file
VMFS-3 3.x-5.x (deprecated) 1-8 MB 2 TB 2 TB
VMFS-5 5.x-7.x 1 MB unified 64 TB 62 TB
VMFS-6 6.0+ 1 MB unified 64 TB 62 TB

VMFS-6 adds: automatic UNMAP, 4K native (4Kn) sector support, SE Sparse improvements.

vSphere 7.0 U1+ dropped VMFS-3 support. vSphere 8.0 does not support VMFS-3. VMFS-5 is supported but VMFS-6 is the default for new datastores.

NFS versions

Version vSphere Auth Multipathing
NFS v3 All AUTH_SYS only Single TCP session, no native MP
NFS v4.1 6.0+ AUTH_SYS, Kerberos (krb5, krb5i) Session trunking

NFS v3 and NFS v4.1 datastores cannot be mounted by both protocols on the same host simultaneously.

vSAN concepts

  • Hybrid vs all-flash. Hybrid uses SSD cache + HDD capacity. All-flash uses SSD cache + SSD capacity. All-flash supports dedupe and compression.
  • Disk groups. 1 cache device + 1-7 capacity devices = 1 disk group. Up to 5 disk groups per host.
  • OSA vs ESA. Original Storage Architecture (OSA) uses disk groups. Express Storage Architecture (ESA), new in vSphere 8, uses a flat NVMe-only "storage pool" with no cache tier. ESA needs vSAN ReadyNodes certified for ESA.
  • Storage policies. FTT (Failures to Tolerate), FTM (RAID-1 mirror, RAID-⅚ erasure coding), stripe width, IOPS limit, force provision.
  • Stretched cluster. Two sites + witness host for quorum.
  • Hosts in vSAN cluster: 2-host (ROBO), 3-64 standard, 96 max in vSphere 8.

Datastore types comparison

Type Backing Use
VMFS Block (FC, FCoE, iSCSI, local) General purpose
NFS NFS server Often used for templates, ISOs, archive VMs
vSAN HCI - local disks aggregated Production HCI
vVols SAN with VASA provider Per-VM granularity, snapshots offloaded to array

High Availability (vSphere HA)

  • Restarts VMs on surviving hosts after a host failure.
  • Master/slave model. One host is the master, talks to vCenter and tracks the cluster.
  • Heartbeats: management network + heartbeat datastores (default 2).
  • Admission control: prevents over-commitment so the cluster can recover from N host failures. Default policy: Cluster resource percentage. Alternatives: Slot policy, Dedicated failover hosts.
  • VM monitoring: restarts a VM if VMware Tools heartbeat stops.
  • Application monitoring: requires SDK integration.
  • Proactive HA: vendor health provider triggers maintenance migration before a host fails.

HA states for hosts

  • Connected, Maintenance, Disconnected, Not Responding, Isolated, Network Partitioned

DRS (Distributed Resource Scheduler)

  • Balances VM placement across hosts based on CPU/memory load.
  • Automation modes: Manual, Partially Automated (placement only), Fully Automated (default).
  • Migration threshold: 1 (conservative) to 5 (aggressive). Default 3.
  • Predictive DRS (with Aria Operations) uses 24h forecasts.
  • DRS rules: VM-VM affinity (keep together), anti-affinity (separate), VM-Host (must / should run on / not run on).

vMotion / Storage vMotion

  • vMotion moves a running VM's CPU/memory state between hosts. Requires shared storage or vSphere 6.0+ with cross-vSwitch / cross-vCenter / cross-VC vMotion.
  • Storage vMotion moves VM files between datastores while running.
  • Long Distance vMotion: up to 150 ms RTT, requires 250 Mbps+ per concurrent vMotion.
  • Encrypted vMotion: Required, Opportunistic (default), Disabled.

vMotion network requirements

  • Dedicated VMkernel adapter with vMotion service enabled.
  • 1 GbE supports 4 concurrent vMotions; 10 GbE supports 8.
  • 25/40/100 GbE supported and recommended for high-density.

Fault Tolerance (FT)

  • Lock-step secondary VM stays in sync with primary. Zero-downtime failover.
  • vSphere 8 FT: up to 8 vCPUs and 128 GB RAM per FT VM.
  • Max 4 FT-protected VMs per host, 8 vCPUs total per host.
  • Requires dedicated 10 GbE FT logging network. Hardware Virtualization (HV) must be enabled.

Lifecycle Manager (vLCM)

Replaces vSphere Update Manager (VUM). Two modes:

  • Baselines (legacy, vSphere 7-8): manage hosts with patch and upgrade baselines.
  • Image-based (vSphere 7+, recommended): single desired-state image (ESXi base + vendor add-ons + components + firmware) applied cluster-wide.

vLCM also patches VMware Tools, VM hardware, and standalone hosts. Image-based clusters cannot mix vendors (e.g., all Dell, or all HPE).


Logs to know (Section 6)

Log Where Contents
vmkernel.log /var/log/ on ESXi VMkernel events: storage, networking, hardware
hostd.log /var/log/ on ESXi Host management agent (vSphere Client to host)
vpxa.log /var/log/ on ESXi vCenter agent on host
vpxd.log /var/log/vmware/vpxd/ on VCSA vCenter Server main log
fdm.log /var/log/ on ESXi HA Fault Domain Manager
vmware.log VM directory on datastore Per-VM log; one per power-on
auth.log, shell.log /var/log/ on ESXi Login / shell activity
syslog.log /var/log/ on ESXi Generic syslog

Bundle support logs with vm-support on ESXi or "Export System Logs" in the vSphere Client.


esxtop counters (high-yield)

Press the listed key in esxtop to switch view.

Key View Critical counter
c CPU %RDY (>10% per vCPU = contention), %CSTP (co-stop, multi-vCPU contention)
m Memory %SWP (swapping = bad), %MCTL (ballooning), N%L (NUMA locality, want >80%)
n Network %DRPTX, %DRPRX (drops)
d Disk adapter DAVG/cmd (device avg latency, want <10 ms), KAVG (kernel, want <1 ms)
u Disk device DAVG, KAVG, GAVG = DAVG+KAVG
v Disk VM Per-VM I/O
i Interrupts CPU interrupt distribution
p Power C-states

Identity, RBAC, SSO

  • vCenter SSO: domain default vsphere.local. First user administrator@vsphere.local.
  • Identity sources: Integrated Windows Authentication, AD over LDAP, OpenLDAP, vsphere.local. AD over LDAPS recommended.
  • Federated identity: vCenter 7.0+ supports OIDC federation with AD FS, Okta, PingFederate, Azure AD/Entra ID.
  • Roles: Default - No access, Read-only, Administrator, plus sample roles (Virtual Machine Power User, Datastore Consumer, Network Administrator, etc).
  • Permissions: assigned at object level (vCenter, datacenter, cluster, host, folder, VM, network, datastore). Permissions propagate down by default.
  • Global permissions (across linked vCenters) vs vCenter-scoped permissions.

Tags and Categories

  • Categories group related tags (e.g., "Environment" β†’ Prod, Dev, QA).
  • Cardinality: One tag per object, or many tags per object (per category).
  • Used for: search, content library publishing, storage policies, DRS host groups, backup product policies.

Content Library

  • Stores templates (OVF/OVA), ISOs, and other files. Replaces ad-hoc template folders.
  • Local library vs Subscribed library (pull from a published one). Subscribed-on-demand vs Subscribed-immediate.
  • Cross-vCenter publish/subscribe is supported.
  • Storage backend: any datastore (VMFS, NFS, vSAN). NFS recommended for large libraries.

Common confusions

  • VUM is gone. vSphere 8 uses vLCM. Don't pick "Update Manager" answers.
  • PSC is gone. Platform Services Controller was retired with vSphere 7. SSO/CA/VMDir now run inside VCSA.
  • External vCenter database is gone. VCSA uses an internal embedded vPostgres database. Windows vCenter Server was retired with vSphere 7.
  • NFS v4.1 with Kerberos and VAAI: VAAI-NAS plugin needed for offloads.
  • APD vs PDL. All Paths Down (APD) is transient; storage might come back. Permanent Device Loss (PDL) is final - array reports the LUN gone. HA reactions differ.
  • HA vs FT. HA restarts VMs (downtime). FT runs a lockstep secondary (zero downtime, but performance cost).
  • Memory ballooning vs swapping. Ballooning is benign reclaim via VMware Tools driver. Host swapping (.vswp) means real RAM exhaustion. Compression is in-between.
  • Reservations vs Shares vs Limits. Reservation = guaranteed minimum. Limit = hard cap. Shares = priority during contention.

High-yield memorization list

  • vSphere 8 maximums table above (per VM, per host, per cluster, per vCenter)
  • VCSA sizing: Tiny / Small / Medium / Large / X-Large host counts
  • License bundles post-Broadcom: VCF vs VVF vs vSphere Standard contents
  • vSwitch teaming modes and when each is required
  • VMFS-5 vs VMFS-6 differences (UNMAP, 4Kn)
  • vSAN OSA disk groups (1 cache + 1-7 capacity, max 5 per host)
  • vSAN ESA storage pool concept (vSphere 8 NVMe-only)
  • HA admission control policies (Cluster resource percentage default)
  • DRS automation modes and migration threshold default of 3
  • FT vSphere 8 limits: 8 vCPU, 128 GB RAM, 4 VMs per host
  • Logs by component (vmkernel, hostd, vpxa, vpxd, fdm)
  • esxtop counters and thresholds (%RDY, DAVG, %SWP)